Daily Thermal Energy Storage in Water-in-Glass Evacuated-Tube Solar Water Heaters: A Paired Experimental Assessment of an Aluminum-Foil Reflector
Yvan René Leiva Calvanapón ,
Elder Marino Mendoza Orbegoso ,
nattan roberto caetano ,
Marcos Antônio Klunk
|
Available online: 10-13-2026

Abstract

Full Text|PDF|XML

Improving the thermal performance of solar water heating systems is an important aspect of sustainable energy use, particularly in applications where solar heat can reduce reliance on conventional water heating. Reflective surfaces can increase the solar radiation reaching evacuated-tube collectors, but their contribution to daily thermal energy storage requires evaluation under comparable operating conditions. This study investigates the difference in daily stored thermal energy between water-in-glass evacuated-tube solar water heaters operated with and without an aluminum-foil reflector assembly. Three systems were tested simultaneously in Trujillo, Peru, including two nominally identical 316 L prototypes with and without a 6.624 m$^2$ aluminum-foil-covered steel reflector and a commercial heater (C) used as a secondary reference. Tank temperatures were measured at three heights, and daily stored-energy gains were calculated over a common monitoring interval of 06:25–18:50 without water withdrawal or replenishment. Twelve paired daily observations were analyzed to assess the differences between the two prototypes. The reflector-equipped prototype (PR) recorded greater stored-energy gains in all 12 observations, with mean daily values of 34.39 MJ compared with 30.56 MJ for the prototype without a reflector (P0). The mean paired difference was 3.83 MJ, corresponding to an overall increase of 12.54%, while individual daily increases ranged from 9.18% to 15.61%. The 95% confidence interval for the mean paired difference was 2.81–4.85 MJ. C recorded a mean daily gain of 26.29 MJ, although differences in capacity and collector geometry prevented a direct assessment of the reflector effect from this comparison. The findings indicate that the aluminum-foil reflector assembly is associated with a consistent increase in daily stored thermal energy under the tested conditions. The study provides experimental evidence for evaluating a relatively simple modification to evacuated-tube solar water heating systems, while distinguishing improvements in stored thermal energy from changes in collector efficiency.

Abstract

Full Text|PDF|XML

Battery energy storage can improve the utilization of available photovoltaic (PV) generation by recovering energy otherwise curtailed under grid export limits, but simplified dispatch models can overlook temperature-dependent changes in usable capacity and power capability. This study investigates how environmental temperature and current-driven self-heating affect curtailment recovery and the adequacy of simplified battery models. Public five-minute weather data for Phoenix were combined with a reduced lithium iron phosphate (LFP) battery model derived from a dynamic electrothermal model independently validated against held-out profiles at 25 and 35 ℃. Annual dispatch simulations compared electrical-only optimization, terminal-state-of-charge-corrected nonlinear replay, and coupled sequential-linearization dispatch. For a 230 MW PV plant with a 195.5 MW export limit and a 30 MW/140 MWh battery, annual curtailment decreased from 39.601 GWh without storage to 8.727 GWh under electrical-only optimization. Nonlinear replay with terminal correction yielded 9.032 GWh, while coupled dispatch reduced this value to 8.956 GWh. On a common 112 MWh usable-energy basis defined at 25 ℃, ambient-driven variation in electrical properties increased annual curtailment by 265.6 MWh relative to a fixed-25 ℃ reference under an exposed-cell thermal boundary. Temperature-dependent usable capacity accounted for most of this difference; alternative empirical capacity maps yielded effects of 233.4–295.5 MWh/year. Current-driven self-heating produced no numerically resolvable annual curtailment effect at the nominal rating. Extending the dispatch horizon from 24 to 48 hours changed annual coupled-dispatch curtailment by 0.0125%. These findings show that weak self-heating alone does not establish the adequacy of a simplified battery model. Comparisons on a common reference usable-energy basis, with consistent terminal state of charge (SOC) conditions and explicit physical-feasibility checks, provide a basis for selecting battery models to assess renewable energy recovery in export-constrained PV-storage systems.

Abstract

Full Text|PDF|XML

Smart charging and vehicle-to-grid (V2G) integration can support renewable-energy utilization and power-system flexibility, but their practical contribution depends on more than the technical capability of individual vehicles and chargers. This review examines the conditions under which demonstrated charging and V2G performance can be translated into dependable services for sustainable energy systems. A critical integrative review was conducted using literature published between 2013 and August 2026. Studies were examined across battery, charger, distribution-network, communication, control, market, regulatory, and user dimensions, with particular attention to operating assumptions, performance baselines, and validation maturity. The reviewed simulations reported a 23.81% reduction in peak load at a photovoltaic (PV)–storage charging station, a 21% reduction in peak demand accompanied by an 18% increase in renewable-energy utilization in a microgrid, and a decrease in total harmonic distortion (THD) from 6.8% to 4.6% in a distribution feeder. These outcomes were obtained under different operating conditions and could not be directly compared. The synthesis identified persistent gaps between component-level performance and dependable deployment, particularly in fleet availability, battery degradation, interoperability, communication reliability, market participation, and field validation. A two-dimensional assessment framework was developed to distinguish installed, connected, controllable, and contractually dependable fleet capability while linking deployment decisions to successive levels of validation evidence. The findings indicate that reliable V2G deployment requires coordinated assessment of technical performance, operational constraints, and participant costs. The proposed framework provides a basis for evaluating deployment readiness and identifying the evidence needed to integrate electric vehicle (EV) flexibility into sustainable energy systems.

Abstract

Full Text|PDF|XML

Ventilation strategies influence the energy demand of passenger-car heating, ventilation, and air-conditioning (HVAC) systems by changing outdoor-air loads, occupant-generated carbon dioxide (CO$_2$) accumulation, and particle ingress. Assessing these competing effects requires consistent treatment of cabin heat transfer, moisture, airflow, and filtration. This study investigates the energy–air-quality trade-offs associated with alternative cabin ventilation strategies using a reduced-order dynamic model. Transient heat and moisture balances were coupled with occupant-generated CO$_2$, fine particulate matter (PM$_{2.5}$) transport and filtration, and HVAC electrical demand. Fresh-air operation, high recirculation, and a rule-based switching strategy were compared in an illustrative 30-min summer simulation with four occupants. Under high recirculation, the predicted end-of-period CO$_2$ concentration reached approximately 7,059 ppm, compared with 1,030 ppm under fresh-air operation. The corresponding PM$_{2.5}$ concentrations were approximately 6.7 and 35.0 μg/m$^3$, while cumulative HVAC electricity use was 0.332 and 0.379 kWh, respectively. High recirculation therefore reduced simulated electricity use by 12.4% but allowed substantially greater CO$_2$ accumulation. The rule-based strategy consumed 0.378 kWh and produced final CO$_2$ and PM$_{2.5}$ concentrations close to those of continuous fresh-air operation. These model-based results indicate that cabin energy savings must be assessed alongside ventilation and pollutant exposure requirements. The framework provides a common basis for comparing HVAC electricity demand and cabin environmental conditions under prescribed ventilation configurations.